Power quality analyzer, multimeter and dual channel oscilloscope with recording capability. FlukeView software is able of logging harmonics and all other readings over time. Read more
Discontinued
Contact
sales team
Compare
Compare
Discontinued
Contact
sales team
Impossible to estimate the shipping cost
Description

Fluke 43B combines the most useful functions of a power quality analyzer, multimeter and dual channel oscilloscope with recording capability. Fluke 43B power quality analyzer tracks voltage, current, frequency, power harmonics, captures voltage sags, transients and inrush current, measures resistance, diode voltage drop, continuity, and capacitance. FlukeView software is able of logging harmonics and all other readings over time and providing a complete harmonics profile up to the 51st harmonic.

Fluke 43B Power Quality Analyzer User Manuals

Download Fluke 43B power quality analyzer applications guide

Download Fluke 43B power quality analyzer starting manual

Download additional information about Fluke 43B power quality analyzer

Download Fluke 43B power quality analyzer software manual

Download software reference for Fluke 43B power quality analyzer

Download Fluke 43B power quality analyzer user manual

Fluke 43B Power Quality Analyzer Features

  • 3-phase power calculation on balanced loads from a single-phase measurement
  • Monitoring functions for intermittent problems and power system performance tracking
  • Two selectable parameters recording for up to 16 days
  • 20 measurement memories to save/recall screens and data with cursor readings
  • Voltage, current power harmonics up to 51st harmonic; THD and phase angle for individual harmonics
    Harmonics
  • Demonstration how to set up 3-phase power measurements
  • Phase
  • Cursors to read time and date of sags and swells
  • Sags
  • Voltage transients and waveform distortion with saving up to 40 transients
  • Transients
  • Watts, power factor, displacement power factor, VA and VAR
  • Power
  • Voltage and current waveforms, true RMS voltage and current, frequency
  • VAH
  • Complete package with voltage probe and current clamp
  • Extended operation time
  • User's/applications manual and power quality video

Fluke 43B Power Quality Analyzer Technical Specifications

Input characteristics
Input impedance 1 MΩ, 20 pF
Voltage rating 600 V rms
Voltage / Current / Frequency display
True RMS voltage (AC + DC) Range 5.000 V / 50.00 V / 500.0 V / 1250 V
Accuracy ±(1% + 10 counts)
True RMS current (AC + DC) Range 50.00 A / 500.0 A / 5.000 kA / 50.00 kA / 1250 kA
Accuracy ±(1% + 10 counts)
Frequency Range 10.0 to 15.0 kHz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Crest factor Range 1.0 - 10.0
Accuracy ±(5% + 1 count)
Power display
Watts, VA, VAR reactive power (1-phase and 3-phase,3 conductor balanced loads) Range 250 W / 2.50 kW/ 25.0 kW / 250 kW / 2.50 MW / 25 MW / 250 MW / 625 MW / 1.56 GW
Accuracy ±(4% + 4 counts) fundamental power
± (2 % + 6 counts) total power
PF (Power factor) Range 0.00 to 1.0
Accuracy ±0.04%
DPF (Displacement power factor) Range 0.00 / 0.25 / 0.90 / 1.00
Accuracy ±0.04
H2 Frequency fundamental Range 40.0 to 70.0 Hz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Harmonics display
Voltage, current, frequency Fundamental VA ±(3% + 2 counts) W ±(5% + 2 counts)
2 to 31st harmonic VA ±(5% +3 counts) W ±(10% +10 counts)
32 to 51st harmonic VA ±(15% +5 counts) W ±(30% +5 counts)
Frequency fundamental Range 40 Hz to 70 Hz
Accuracy ±0.25 Hz
Phase Range 10.0 to 15.0 kHz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Frequency V, A (between Fundamental & Harmonics) ±3º to ±15º
W (between Voltage Fundamental & Current Harmonics) ±5º to ±15º
K-factor (current and power) Range 1.0 to 30.0
Accuracy ±10%
THD (Total harmonic distortion) Range 0.00 - 99.99
Accuracy ±(3% + 8 counts)
Sags and swells
Recording times 4 min to 16 days (selectable)
Vrms actual, Vrms max, min(AC + DC) Range 5.000 V / 50.00 V / 500.0 V / 1250 V
Accuracy readings ±(2% +10 counts); cursor readings ± (2% + 12 counts)
Arms actual, Arms max, min (AC + DC) Range 50.00 A / 500.0 A / 5.000 kA / 50.00 kA
Accuracy ±(2% +10 counts)
Transient capture
Minimum pulse width 40 ns
Useful bandwidth input 1 DC to 1 MHz
Number of transients 40
Voltage threshold settings 20%, 50%, 100%, 200% above or below reference
Reference signal after START, the Vrms and frequency of the signal are measured. from these data a pure sinewave is calculated as reference for threshold setting.
Vpeak min, Vpeak max at cursor Range 10 V / 25 V / 50 V / 125 V / 250 V / 500 V / 1250 V
Accuracy ±5% of full scale
Resistance, Capacitance, Diode, Continuity
Resistance Range 500.0 Ω / 5.000 kΩ / 50.00 kΩ / 500.0 kΩ / 5.000 MΩ / 30.00 MΩ
Accuracy ±(0.6% + 5 counts)
Capacitance Range 50.00 nF / 500.0 nF / 5.000 µF / 50.00 µF / 500.0 µF
Accuracy ±(2% + 10 counts)
Diode voltage Range 0 to 3.000 V
Accuracy ±(2% + 5 counts)
Continuity beeper at < 30 Ω ± 5 Ω
Max current 0.5 mA
Temperature °C or °F
Inrush current
Inrush times 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
Current Range 1 A / 5 A / 10 A / 50 A / 100 A / 500 A / 1000 A
Accuracy ±5% of full scale
Cursor readings peak max at cursor 1 and cursor 2
Time between cursors Range 4 to 235 pixels (1 pixel = inrush time/250)
Accuracy ±(0.2% + 2 pixels)
Temperature Range -100 °C - 400 °C
Accuracy ±(0.5% + 5 counts)
Scope display
Measurements DC, AC, AC+DC, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
Time ranges 20 ns/div to 60 s/div
Max sampling rate 25 MS/s
Bandwidth Voltage channel [1] 20 MHz at inputs, 1 MHz with TL24 Leads
Current channel [2] DC to 15 kHz at inputs, 10 kHz with i400s current clamp
Coupling AC, DC (10 Hz - 3 dB)
Vertical sensitivity 5 mV/div to 500 V/div
Vertical resolution 8 bit (256 levels)
Record length 512 samples per channel
Base ranges 60 S/div to 20 nS/div ± (0.4% + 1 pixel)
Timebase modes normal, roll, single
Pre-trigger up to 10 divisions
Trigger source input 1 or Input 2 or automatic selection
Trigger mode automatic Connect-and-View™, Free Run, and Single Shot
Connect-and-View advanced automatic triggering that recognizes signal patterns
automatically adjusts triggering, timebase and amplitude and displays stable pictures
Memories 20 (screens, settings, data)
Other specifications
Operating temperature 0°C to +50°C
Battery rechargeable NiMH pack (charger included), 6.5 hrs extended operating time (continuous)
Dimensions, mm 232 x 115 x 50
Weight, kg 1.1

Fluke 43B Power Quality Analyzer Package

  • Power quality analyzer Fluke 43B (1 pc.)
  • Infrared thermometer Fluke 61 (1 pc.)
  • Flat-tipped slim-reach test probes Fluke TP1 (1 set)
  • Test leads Fluke TL24 (1 set)
  • Industrial test clips Fluke AC20 (1 set)
  • Round slim-reach 4 mm test probes Fluke TP4 (1 set)
  • AC current clamp Fluke i400s (1 pc.)
  • Voltage probe Fluke VPS40 (1 pc.)
  • Large jaw alligator clips Fluke AB200 (1 set)
  • Banana-to-BNC adapter Fluke BB120 (1 pc.)
  • Optically isolated USB interface adapter Fluke OC4USB (1 pc.)
  • Rechargeable NiMH battery pack Fluke BP120MH (1 pack)
  • Line voltage adapter/battery charger Fluke PM8907 (1 pc.)
  • Hard case Fluke C120 (1 pc.)
  • Software and user's manual on CD-ROM Fluke SW43W (1 pc.)
  • Users manual and application guide (1 pc.)
Product specifications, appearance and package content may differ from those presented on the website and can be changed without notice. Please, contact sales manager before purchase.
All rights reserved. This material from gsmserver.com web site may not be published, rewritten or redistributed in whole or part without authorship indicated and backlinks provided.
Delivery
Payment
Warranty

Customers Feedback

Chat with us
English Online Español Online Português Offline Tech Support Online
Sales chat
 English online
 Español online
 Português offline
 Tech Support online
Contacts
Phone:
Email:
Compare
No items in compare list
Sales chat
Contacts
Compare