Digital Storage Oscilloscope ATTEN ADS1062CM
id: 818652
5.5 kg 110, 220 V Warranty: 24 months
Desktop 2 channel digital storage oscilloscope. Bandwidth 60 MHz. Sampling frequency 1 GSa/s. Memory Depth 40 Kpts/ 2 Mpts. Read more
Buy wholesale and save
ATTEN ADS1062CM is a digital storage oscilloscope with top performance and various advanced functions. It has 2 channels, 60 MHz bandwidth, sampling frequency of 1 GSa/s and 2Mpts memory depth.
Features
- 1GSa/s sampling rate and 50 GSa/s equivalent sampling rate
- 2 Channels
- 5.7" Color LCD
- 12 menu languages - English, French, German, Russian, Spanish, Simplified Chinese, Traditional Chinese, Portuguese, Japanese, Korean, Italian, Arabic
- Memory Depth: 40Kpts/ 2Mpts
- Trigger types: Edge, Pulse Width, Video, Slope, Alternative
- Unique digital filter function and waveform recorder function
- Support Pass/Fail function.
- Thirty two parameters Auto measure function.
- Save/recall types: setups, waveforms, CSV file, picture
- Support Multilingual On-line help system
- Adjustable waveform intensity and grid brightness
- Easyscope Software
- Standard Configuration Port:
- USB Host: Support USB flash driver save/recall function and update firmware;
- USB Device: Support PictBridge compatible printer and support PC remote control;
- RS232, Pass/ Fail output.
Comparative Specifications for ATTEN ADS1000CM/C Series Digital Storage Oscilloscopes
Model | ADS1152CM | ADS1102CM | ADS1062CM | ADS1042CM | ADS1022C |
---|---|---|---|---|---|
Bandwidth | 150 MHz | 100 MHz | 60 MHz | 40 MHz | 25 MHz |
Sampling Rate | 1 GSa/s | 500MSa/s | |||
Equivalent Sampling Rate | 50 GSa/s | ||||
Memory Depth | Single Channel: 40Kpts/2Mpts; Double Channels: 20Kpts/1Mpts | 4Kpts | |||
Rise Time | <2.3ns | <3.5ns | <5.8ns | <14ns | |
Input Impedance | 1MΩ || 13pF | ||||
Sec/div Range | 2.5ns/div-50s/div | 5ns/div-50s/div | 25ns/div-50s/div | ||
Scan: 100ms-50s/div | |||||
Display | Color LCD (320×234)5.7" LCD |
ATTEN ADS1062CM Digital Storage Oscilloscope Technical Specifications
Input | ||||
---|---|---|---|---|
Input Coupling | AC, DC, GND | |||
Input Impedance | DC: 1MΩ ± 2% || 17pF ± 3pF AC: 1.2 MΩ ± 2% || 17pF ± 3pF, < =100mV/div 1.0 MΩ ± 2% || 17pF ± 3pF, >100mV/div |
|||
Maximum Input Voltage | ± 400V PK-PK CATI | |||
Ch to Ch Isolation (Both channels in same V/div setting) |
>100:1 at 30 MHz | |||
Probe attenuator | 1X, 10X | |||
Probe attenuator | 1X, 10X, 100X, 1000X | |||
Horizontal System | ||||
Real Time Sampling Rate | Single Channel 1GSa/S; Double Channels 500MSa/s | |||
Equivalent Sampling Rate | 50GSa/s | |||
Measure Display Modes | main, window, window zoom, scan, x-y | |||
Timebase Accuracy | ±100ppm measured over 10 ms interval | |||
Time Window | 12 Divisions | |||
Horizontal Scan Range | 5.0 ns/div -50s/div Scan: 100 ms/div -50s/div (1-2.5-5 sequence) |
|||
Vertical System | ||||
Vertical Sensitivity | 2mV-10V/div at input BNC (1-2-5 order) | |||
Channel voltage offset range | 2 mV-200mV: ±1.6V 206mV-10V: ± 40V in Fixed Gain Ranges & Variable Gain Ranges |
|||
Vertical Resolution | 8 bit | |||
Channels | 2 | |||
Analog Bandwidth (at input BNC) | 60 MHz | |||
BW Flatness | DC-10% of rated BW: ± 1dB 10%-50% of rated BW: ± 2dB 50%-100% of rated BW: ± 3dB |
|||
Lower frequency limit (AC -3dB) | ≤10 Hz (at input BNC) | |||
Noise: Pk-Pk for 3K record | ≤ 0.6 Div for average of 10Pk-Pk readings in fixed gain settings.
< = 0.7 Div for average of 10 Pk-Pk readings, Variable gain settings |
|||
SFDR including harmonics | ≥ 40dB | |||
DC Gain Accuracy | < ± 3.0%: 5mV/div to 5V/div in Fixed Gain Ranges < ± 4.0%:typical for 2mV/div and Variable Gain Ranges |
|||
DC Measurement Accuracy: All Gain settings ≤100mV/div |
± [3%X (|reading|+|offset|) +1% of |offset| +0.2div+2mV] +0.2div+2mV] |
|||
DC Measurement Accuracy: All Gain settings>100mV/div |
± [3%X (|reading|+|offset|) +1% of |offset| +0.2div+100mV] | |||
Rise time, Typical (using 500ps pulse) |
<5.8ns | |||
Math operation | +,-, *,FFT | |||
FFT | Window mode: Hanning, Hamming, Blackman, Rectangular | |||
Bandwidth limiter | 20MHz ± 40% Typical (Note: BW limited below 20MHz ± 40% when using probe X1) | |||
Trigger System | ||||
Trigger Types | Edge, Pulse Width, Video, Slope, Alternative |
|||
Trigger Modes | Auto, Normal, Single | |||
Trigger Sources | Ch1-2, EXT, EXT/5, AC Line | |||
Trigger Coupling | AC, DC, LF rej, HF rej | |||
Trigger Level Range | CH1, CH2: ±6divisions from center of screen EXT: ±1.2V EXT/5: ± 6V |
|||
Trigger Level Accuracy (typical) applicable for the signal of rising and falling time ≥ 20ns | Internal: ±(0.2 div×V/div)( within ± 4 divisions from center of screen)
EXT: ±(6% of setting + 40 mV) EXT/5: ±(6% of setting + 200 mV) |
|||
Edge Trigger | Edge type: Rising, Falling, Rising and Falling | |||
Pulse Width Trigger | Trigger Modes: (>,<,=) Positive Pulse Width, (>,<,=)Negative Pulse Width Pulse Width Range: 20ns-10s | |||
Video Trigger | Support signal Formats: PAL/SECAM, NTSC Trigger condition: odd field, even field, all lines, line Num |
|||
Slope Trigger | (>,<,=) Positive slope, (>,<,=)Negative Slope Time: 20ns-10s |
|||
Alternative Trigger | CH1 trigger type: Edge, Pulse, Video, Slope CH2 trigger type: Edge, Pulse, Video, Slope |
|||
Control Panel Function | ||||
Auto Set | Auto adjusting the Vertical, Horizontal system and Trigger Position | |||
Save/Recall | Support 2 Group referenced Waveforms, 20 Group setups, 20 Group captured Waveforms internal Storage/Recall function and USB flash driver storage function. |
|||
Hard Ware Frequency Counter | ||||
Reading resolution | 6 Bytes | |||
Accuracy | ± 0.01% | |||
Range | DC Couple, 10Hz to MAX Bandwidth | |||
Signal Types | Satisfying all Trigger signal (Except Pulse width trigger and Video Trigger) | |||
Acquisition System | ||||
Sample Types | Real time, Equivalent time | |||
Memory Depth | Channel Mode | Sampling Rate | Short memory | Long Memory |
Single Channel | 1GS/s | 40kpts | No Support | |
Single Channel | 500 MSa/s or lower 20kpts -500 MSa/s | 20 Kpts | 2 Mpts | |
Double Channels | 500 MSa/s or lower 20kpts -500 MSa/s | 20 Kpts | 1 Mpts | |
Sample Mode | Sample, Peak Measure, Average | |||
Averages | 4,16,32,64,128,256 | |||
Measure System | ||||
Auto Measure |
Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean, Crms, Vrms, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Rise time, Fall time, Freq, Period, +Wid, -Wid, +Dut, -Dut, Bwid, Phase, FRR, FRF, FFR, FFF,LRR,LRF, LFR, LFF | |||
Cursor Measure | Manual mode, Track mode and Auto mode | |||
Display | ||||
Display Mode | Color TFT 5.7" (145mm) diagonal Liquid Crystal Display | |||
Resolution | 320 horizontal by 234 vertical pixels | |||
Display Color | 64K color | |||
Display Contrast (Typical state) | 150:1 | |||
Backlight Intensity (Typical state) | 300 | |||
Wave display range | 8 x 12 div | |||
Wave Display Mode | Point, Vector | |||
Point, Vector | Off, 1 sec, 2 sec, 5 sec, Infinite | |||
Menu Display | 2 sec, 5 sec, 10 sec, 20 sec, Infinite | |||
Skin | Succinct | |||
Screen saver | 1min, 2min, 5min, 10min,15min, 30min, 1hour, 2hour, 5hour, off | |||
Waveform Interpolation | Sin(x)/x, Linear | |||
Color model | Normal , Invert | |||
Language | English, French, German, Russian, Spanish, Simplified Chinese,
Traditional Chinese, Portuguese, Japanese, Korean, Italian, Arabic |
|||
Interface | USB Host, USB Device, RS232, Pass/Fail output | |||
Power Supply | ||||
Input Voltage | 100-240 VAC, CAT II, Auto selection | |||
Frequency Scope | 45 Hz to 440 Hz | |||
Power | 50VA Max | |||
General Characteristics | ||||
Dimension (L × W × H), mm | 305 × 133 × 154 | |||
Weight | 2.3 kg |
Product specifications, appearance and package content may differ from those presented on the website and can be changed without notice. Please, contact sales manager before purchase.
All rights reserved. This material from gsmserver.com web site may not be published, rewritten or redistributed in whole or part without authorship indicated and backlinks provided.
Screen Size |
|
Number of channels |
|
Storage Capacity |
|
Bandwidth |
|
Type |
|